IIC - 142
Bio Safety Cabinet
Working Table of S.S. 304 grade.Body of
construction can be of Wodden/Mild Steel/Stainlesss Steel
HEPA of 0.3 u of an efficiency of 99.97%
down to 0.3u media is of glass fiber &, made of pleated back &, frow
made of aluminium foil &, packed in a anodized aluminium frame.
Pre filter of dry fiber washable type
with the frame.
Air flow: 70% recirculation 8s 30%
exhaust.
Statically balanced motor blower
assembly.
Outer casing MS sheet duly painted
having provision for capillary
& Thermometer for testing.
Velocity at output of HEPA is 90+20 FPM.
Static Pressure Manometer.
Transparent front Door.
Normal working fluorescent light.
UV light IX 15/30 watts.
Gas cock.
Available In :-
- Class-II, Type-A2 .
- Class-II, Type B2 (Total Exhaust Model)
Options :-
- Virus Burnout System
- HEPA fllter in Exhaust
- Magnehelic Gauge
- Glove Port
SIZE :-
2'X2'X2'
3'X2'X2'
4'X2'X2'
6'X2'X2'
IIC - 144
Loss On Heating/Thin Film Oven
(For Bitumen)
 |
 |
|
|
Precise, Hot
Air Drying.
Better Mineral / Blanket Insulation for
high Temperature & to avoid heat loss.
Silent Hot Air Blower, Unique design of
Air Circulation provide throughout uniform Air movement.
Unique design of ventilation keeps the
surface of the instruments from being Burnt even when the instruments i.e.
Oven Temperature maintained at 200°C.
Polish / Hair Line 304 grade S. Steel
sheet interior, long operation, corrosion resistant.
Kanthal A-1 Super quality coil shaped &
Air heater tubular model wound on side/on the back of the Oven for better
accuracy.
Full feature with Digital Temperature
Controller cum Indicator having Alarm facility (On Customer request).
Toughened Glass view window to observe
/Test the material without disturbing the Temperature condition of the
chamber.
Working Temperature required as per IS:
ASTM is 163°C ± 1 °C.
Provide with detachable metal shaft
(Both for Loss on Heating /Thin Film Oven).
Reduction gear is fitted from outside
rotated by a vertical shaft having 5-6 RPM.
APPLICATIONS :
For Bitumen Testing Loss of weight, softening Paint, Penetration Loss of wt
in Bitumen & Flux Oils (For Construction / Koad Projects Department/
Industries)
 |
Model |
IIC 144 Thin Film Oven |
IIC 144 A Loss oN Heating Oven |
Capacity (Liter) |
60 Liter |
60 Liters |
Interior (mm) |
400 x400 x400mm
16" x 16" x 16" |
400 x 400 x 400mm
16" x 16" x 16" |
Heater Wattage |
1.5 KW. |
1.5 KW. |
No. of Plate Rotating |
One (1 No.) |
One (1 No.) |
|
 |
Technical Parameters :
- Control Panel : Mains & Load Indicator Fine Temperature
Controller, Digital TemperatureController, Fan Switch, Rotating
Motor, Control Switch.
- Temperature Range : Ambientto±250°C
- Temperature Stability : ±1°Cmax
- Material : CRC / MS sheet duly powder coated
- Power Consumption : 220/230V AC Supply 50 HZsingle Phase
- Safety Function : Temp. Overshoot Alarm
- Interior : S. Steel 304 Grade Steel Sheet
- Temperature Setting : 1°C
- Temperature Sensitivity : 1°C
- Optional : RS 232 Communication interface