IIC - 166
CANNING RETORT
With Pressure
Gauge, With Safety Valve, With Release Valve.
Available In Size
Suitable to hold 21 cansof A2-1 /2size -1 IC 166 A.
Suitable to hold 75 cans of A 2-1 /2size. - IIC 166 B.
Suitable to hold 90 cans of A 2-1 size. - IIC 166 C.
Suitable to hold 280 cans of A2-/2size - IIC 166 D.
IIC - 167
AUTOMATIC FLASH POINT APPRATUS
(Price on Request)
 |
|
|
IMPACT
Automatic flash point and fire-point test method is a dynamic method and
depends on definite rates of temperature increases to
control the precision of the
method.
Its primary use is for viscous materials
having a flash point below79°C (175°F)
except fuel oils, to define the hazards of flammable and
combustible materials used
in shipping and safety regulations. The temperature of
the approximately 70 ml test
specimen is increased rapidly at first and then at a
slower constant rate as the flash
point is approached. At specified intervals a test flame
is passed across the cup, to
measure the tendency of the test specimen to form a
flammable mixture with air
under controlled laboratory conditions.
The flash point is the lowest liquid
temperature at which application of the flame
causes the vapors of the test specimen of the sample to
ignite.
To determine the fire-point, the test is
continued until the application of the test flame causes the test specimen
to ignite
and sustain burning for a minimum of 5s
It is an automatic flash and fire-point
tester used to examine liquid as well as highly viscous samples in the same
instrument without any additional equipment for
temperature range up to 400°C. For substances with unknown flash
points, the APPARATUS has a special search mode program.
During the entire heating period, the
test flame is moved across the sample at suitable intervals. The expected
flash
point of a specimen can there by be found in a time
saving and economical manner.
Optional
The UNIT is equipped with:
Standard Cup : with handle, made of brass
Temperature Probe Pt-100 : For sample temperature
Battery operated (1.5 V pencil type cell) Gas igniter :
For LPG gas ignition (Manually operated)
Flame Detection Unit : For the detection of flash- and
fire-points by UV sensor.
Heating : By electrical SS Tubular Cartridge Heater of
suitable rating to maintain ramp rate & easily
DC Motors : Flame Arrest Coverfor extinguishing the
fire in the cup : Flame movement, LID Open/Close, Assembly of sensor
RTD(Pt-100 thermocouple) Up/Down mechanism PC Interface Programmed
ControllerThe Unit is incorporated with MODBUS RTU PC interface
Microprocessor based PID Programmable controller userfriendly features.(PC
operated system through RS232 cable connection as option at extra cost)
IMPACT" Automatic Flash and Fire point apparatus (By Cleveland Open
Cup Method)
Temp Range : Ambient to 400°C with RTD sensor as
Thermocouple
Flame-Detector : UV based flame-detector sensor &
Controller
DC motors : Flame movement, LID Open/Close, Assembly of
sensors Up/Down mechanism. Microprocessor based Program process controller
cum indicator with 3-wire RTD temperature sensor, free potential flame
detector sensor as i/p and DC V SSR
Controller : As o/p.
Equipment Overall Size (LxWxH) : 24"x14"x31"
Equipment Gross Weight : 21 Kg.
Supply : 230 V, 1-0,50 Hz supply with proper earthing
system for Controller.
IIC - 168
DIGITAL ABEL FLASH POINT APPRATUS
This method determines the dosed cup flash points
of petroleum products and mixtures to ascertain whether they give off
inflammable vapour below 73°F or 49°C. The instrument comprises of
electric heater at bottom and is supplied with a water bath cup coverfitted
with stirrer, Digital Temperature Indicator & Electronic Temperature
Regulator, sockets & stand.